Abstract:
Objective A method for the determination of the total iron content in high-iron manganese ores was studied, the determination method of the total iron content in high-iron manganese ores uses phosphoric acid and nitric acid decomposition of samples and titration with potassium dichromate was established. Method Using phosphoric acid and nitric acid to decompose the sample, hydrochloric acid was used to reduce high valence manganese in the determination solution, titanium trichloride was used to reduce trivalent iron in the determination solution, using sodium diphenylamine sulfonate as an indicator, potassium dichromate was used to oxidize the divalent iron to trivalent iron, and calculate the total iron content in high-iron manganese ore based on the amount of potassium dichromate used. Result The determination results by this method were consistent with national standard methods (GB/T 1508-2002), validation using national standard substances, the determination results were consistent with the recognized values. The relative standard deviations (RSD,
n=8) were between 0.26% and 0.53%. Conclusion This method is suitable for the determination of total iron in high-iron manganese ore with a mass fraction ranging from 0.5% to 46.0%. The method has the advantages of a wide determination range, simple operation, fast analysis speed, good reproducibility and accurate results, and can be used as a quantitative detection method for total iron in high-iron manganese ore.